You are:
The INFINEED lt;Gravity lt; 3-ways infusion set without DEHP, BPA-free was
designed to minimize the environmental impact of the device. Two methods
have been used: first, by reducing the plastic mass used by around 10%,
without making any changes to functionality; second, by exclusively
using raw materials that are free from endocrine disruptors (elimination
of components comprising DEHP or BPA.) Residual volume: 18.9 ml
The polycarbonate-free
3-way stopcock has been tested at pressures well above those recommended
for gravity infusion; laboratory tests have shown a pressure resistance
of approximately 10 bar.
Infusion set with:
- Two-channel perforator with grip wings
- Air intake: with 0.2µm filter. Delivered closed for immediate use on infusion bags.
- Chamber: Soft and translucent, the chamber is calibrated at 20 drops = 1ml ± 0.1ml. 15µ particle filter.
- Flow regulator: ABS linear flow control for good roller clamp rigidity, precision and reliability.
- BPA-free 3-way stopcock: Lipid-resistant with large valve stopcock and
arrows indicating the direction of flow, permanently attached to the
extension tube. Only the main line can be disconnected from the
stopcock.
- Tubing: PVC (DINCH) designed for comfort, optimal flow adjustment consistency and to prevent kinks. Diameter: 3 x 4.1mm
- End connector: Mobile Luer Lock
- End stopper: 0.8 µm purge filter with hydrophobic membrane
Length: 150cm+60cm
Indications
This device enables the parenteral administration by gravity of injectable preparations: parenteral drugs, solutions and nutrition.
For peripheral lines, the infusion line can remain in place for a maximum of 96 hours (i.e. the maximum time the peripheral catheter can be in place).
For central lines, the infusion line must be changed at least every 72 hours (or according to the institution's validated protocol).
Used materials
PVC DINCH (DEHP<0.1%(m/>)): Chamber, air intake, tubing - Polypropylene: Protective cap, stopcock stopper - Polyethylene: Stopcock valve, purge filter - Tritan® BPA-free: Stopcock body - Acrylonitrile butadiene styrene: Perforator, regulator, mobile Luer Lock - Nylon: Particle filter
Labeling
on each unit are written the reference, the lot/serial number, the sterilization method and the expiry date if applicable
medical device
sterile
conformity
economic operator
Transport conditions
Protect from light and humidity and store at a temperature between 5°C and 20°C.
Conditioning | Parts quantities | Dimensions in cm | Weight in kg | Ean 13 of conditioning |
UNIT | 1 | 10 x 25 x 1 | 0.031 | 3661809029394 |
BAG | 25 | 48 x 30 x 1 | 0.778 | 3661809129391 |
CASE | 250 | 58 x 40 x 25 | 8.000 | 3661809229398 |